FP 400Y-7DM

The BERMAD model 400Y-7DM utilizes an elastomeric deluge valve, designed specifically for advanced fire protection systems and the latest industry standards. Electric-Pneumatic Double interlock systems include automatic sprinklers attached to a supervised dry sprinkler piping system and a supplementary electric detection system. The 400Y-7DM admits water into the sprinkler system piping only when both the electric detection device and the pneumatic supervised systems are simultaneously activated. An anti-flooding feature is provided by using an in-line check valve, which creates an intermediate vented chamber using a Normally Open drip check. As an option the 400Y-7DM features a quarter turn valve position indicator available with limit switches for remote valve position monitoring.

FP 400Y-7M

The BERMAD Model FP 400Y-7M is an elastomeric deluge valve, designed for advanced fire protection systems and the latest industry standards.
The Single Interlock Electric Release is suitable for use in systems requiring that water be kept out of the sprinkler piping until an electric detecting device activated.

The Single Interlock Pre-Action Systems include automatic sprinklers attached to a dry sprinkler piping system, with a supplementary electric detection system installed in the same area. This system admits water into the sprinkler piping upon activation of the detection system. Water is discharged only through sprinklers that have been opened due to excessive heat.

When a Supervised System is required, a pneumatic low pressure supply shall be provided through a proper Air Maintenance Device (AMD-74 or 75), also an antiflooding feature is provided by utilizing an in-line check valve, which creates an intermediate vented chamber using a Normally Open drip-check.
As an option the 400Y-7M features a visual quarter turn valve position indicator, available with limit switches for remote valve position monitoring.

 

FP 400Y-7BM

The BERMAD Model FP 400Y 7BM is an elastomeric deluge valve, designed for advanced fire protection systems and the latest industry standards.
The Double Interlock Pre-Action is suitable for use in systems requiring that water be kept out of the sprinkler piping until an electric detecting device and a sprinkler have both been activated.
Electric-Electric double interlock systems include automatic sprinklers attached to a dry sprinkler piping system with a low air pressure switch, along with a supplementary electric detection system which are both wired to a Cross-Zone
releasing control panel.
Model FP 400Y-7BM Pre-Action System admits water into the sprinkler piping only when both the detection device and the supervised systems simultaneously signal the control panel to trigger the solenoid valve.
An anti-flooding feature is provided by using an in-line check valve, which creates an intermediate vented chamber using a Normally Open drip-check.
As an option the 400Y 7BM features a visual quarter turn valve position indicator, available with limit switches for remote valve position monitoring.

 

FP 400E-DP

The BERMAD Model 400E-DP, Dry Pipe Control Valve, is suitable for dry pipe systems with automatic sprinklers attached to a dry sprinkler piping system, with a supplementary electric monitoring system and a Pneumatic Supervised System of air pressure in the system piping,installed in the same area. The Supervised System consists of a Pneumatic Pilot Valve, pneumatic low pressure supply, and an additional listed check valve, including trim with low pressure switch, installed downstream from the Control Valve.

 

FP 400E-7M

The BERMAD Model FP 400E-7M Single Interlock Pre-Action Release System is suitable for use in systems requiring that water be kept out of the sprinkler piping until an electric detecting device has been activated. Single Interlock Pre-Action Systems include automatic sprinklers attached to a dry sprinkler piping system, with a supplementary electric detection system installed in the same area. This system admits water into the sprinkler piping upon activation of the detection system.Water is discharged only through sprinklers that have been opened due to excessive heat. When a Supervised System is required, a pneumatic low pressure supply shall be provided. An anti-flooding feature is provided by utilizing an in-line check valve, which creates an intermediate vented chamber using a Normally Open drip-check.

 

FP 400E-7DM

The BERMAD Model FP 400E-7DM Double Interlock Pre-Action, Electric-Pneumatic Release System is suitable for use in systems requiring that water be kept out of the sprinkler piping until an electric detecting device and a sprinkler have both been activated. Electric-Pneumatic Double Interlock Systems include automatic sprinklers attached to a dry sprinkler piping system, with a supplementary Electric Detection System and a Pneumatic Supervised System of low air pressure in the system piping. The Supervised System consists of a Pneumatic Pilot Valve (PORV), and pneumatic low pressure supply. The Double Interlock Pre-Action System admits water into the sprinkler piping only when the detection system triggers the solenoid valve through the control panel, while the PORV is simultaneously activated due to the pressure drop in the Supervised System. An anti-flooding feature is provided by utilizing an in-line check valve, which creates an intermediate vented chamber using a Normally Open drip-check.

 

FP 400E-7BM

The BERMAD Model FP 400E-7BM Double Interlock Pre-Action, Electric-Electric Release System is suitable for use in systems requiring that water be kept out of the sprinkler piping until an electric detecting device and a sprinkler have both been activated. Electric double interlock systems include automatic sprinklers attached to a dry sprinkler piping system, along with a supplementary electric detection system and an electric Supervised System of low air pressure in the system piping. The Double Interlock Pre-Action System admits water into the sprinkler piping only when both the detection device and the supervised systems simultaneously signal the control panel to trigger the solenoid valve. An anti-flooding feature is provided by utilizing an in-line check valve, which creates an intermediate vented chamber using a Normally Open drip-check.